Metal ECO implementation using Mask Programmable cellsTilak Wadhwa, Gaurav Gupta (NXP Semiconductor, India) Introduction- In deep sub-micron node SOCs with multimillion gates, along with the increase in design complexity, chances of functional ECOs (engineering change orders) is equally increasing. Metal ECOs play a vital role in absorbing such last minute design changes before tapeout and hence help save millions in terms of mask cost. They also help avoid all layer mask change in re-spins to fix IP bugs found from Si Validation. Though design fix belongs to logical domain, physical aspects of implementation are poorly understood. In this article, we will focus on metal ECO implementation methodologies with emphasis on mask programmable cells. Traditional Approach- Generally, metal ECOs are implemented using spare cells which are inserted during synthesis or P&R in the form of ‘spare modules’. A spare module definition mostly includes a wide variety of combinational & sequential cells. For Example - a minimum set will involve multiple instances & various drives of BUF, INV, NOR, NAND, MUX, FF & Latch cells. These spare modules are then sprinkled across the chip/block during P&R (refer pic 1 below). The input pins of functional cells in a spare module are generally tied using TIEHI/LO cells so that they don’t remain floating as these cells are going to be unused till they get used for an ECO. Pic 1 – spare modules distribution in a block There are some inherent problems in this approach due to its probabilistic nature -
Mask Programmable ECO methodology- This methodology addresses the problems of traditional approach to a large extent. Though it has been there in industry for a while now and most EDA tools & library vendors support the usage, there is lesser awareness in wider designer community. Understanding the ECO library- Most library vendors include ECO Kits as part of their library offering (subject to IP licensing). These kits generally include 2 type of cells –
Note the difference of only contact layers in Pics 2a & 2b. ECO implementation flow-
Note that decap benefit will be lost if swap is made using ECO decap cell. Comparative analysis- Let’s first look at the leakage comparison. Table-1 below presents the data on a block in 28nm. Evidently, leakage numbers remain unchanged with ECO filler while spare cells add to leakage power.
Table – 1 (Leakage comparison on a block with ~1K functional spare cells) Above numbers are for a small block with ~0.47M flops. On a full chip design with ~2.9M flops (and 44.5K spare cells), leakage benefit seen is ~110 mw. Summarized below are all advantages of this methodology over traditional approach- Pros –
Cons –
Conclusion- Mask programmable cells methodology has clear advantages over traditional spare cell approach not only in terms of ease and increased probability of a metal ECO implementation but also in leakage power savings. Though, there can be ECO situations where it is probable that spare cells are available and are sufficient for the fix, hence additional mask cost of contact layer can be saved. However, in situations which warrant an all layer change due to non-availability of required spare cells in a certain chip area, pre-filler programmable fillers can surely save FEOL layers change. About the authors- Tilak Wadhwa is currently working as Staff Design Engineer at NXP Semiconductor, India. He has more than 10 years of experience in Chip Level Implementation of Microcontrollers and Block Level Implementation for Complex ASICs with emphasis on P&R, LVS, DRC and DFM. He has also worked previously on RTL2GDSII of High speed DDR/DDLL interfaces and Core Cell Library development & characterization. He can be reached at – tilak.wadhwa@nxp.com Gaurav Gupta is working as STAFF Design Engineer at NXP Semiconductor, India. He has over ten years of industry experience in various fields of VLSI and is currently working in physical design team. He has experience in logical and Physical Synthesis, STA, Static Low Power Verification, Formal Verification and has also worked in Standard Cells library characterization and validation domain. His mail ID is g.gupta@nxp.com If you wish to download a copy of this white paper, click here
|